Triangle Tube owners, please read (updated November 2026): Triangle Tube’s own website states that the company ceased operations effective November 3, 2025. It says spare parts will be sold through its stocking distributors as long as parts remain available, and that purchases made from that date carry no warranty.
If you have a Triangle Tube boiler or combi in Greater Vancouver, ROMA Heating & Cooling still services and repairs these units where parts can be sourced, and can lay out replacement options if a key part is no longer available. Send a photo of the rating plate to info@romaheating.ca or call (604) 704-0300. Licensed gas contractor, Technical Safety BC LGA0202903.
More ROMA services in Vancouver
Why is my Triangle Tube boiler heating water but not the house?
Most Triangle Tube boilers we service are paired with an indirect hot water tank, and the boiler gives that tank priority. In a cold snap, if the tank calls often or the boiler is struggling, the heating zones wait their turn, so you get a hot shower and cold bedrooms. A stuck zone valve or tired circulator does the same.
The scene is familiar: six in the morning, the shower ran hot, but the radiators or in-floor loops never warmed up and the thermostat is still asking for heat. Sometimes the cause is simple priority logic doing its job on the coldest days. More often, something is slowing the boiler down. After a summer of light use, circulator pumps can stick, zone valves can seize part-open, and air collects at high points in the piping. Our soft Lower Mainland water means the dirt in these systems is magnetite and sediment from steel pipe and older radiators, not mineral deposits, and it gradually narrows the heat exchanger's passages.
Cold, wet weather adds outdoor problems too: a condensate line that freezes where it exits the wall, an outdoor temperature sensor that has corroded or been knocked loose, and vent terminals partly blocked by snow or windblown debris. Any one of those can turn a reliable boiler into one that short-cycles or locks out on the nights you need it most.
Which checks are safe for a homeowner, and when do I stop?
Safe checks are limited to the thermostat, the boiler's display, the pressure gauge and a look at the outside vent and drain. Opening the boiler, bleeding radiators on a pressurised system you're unsure of, adding water, or touching gas or venting parts should be left to a licensed technician.
- Set each zone thermostat to heat and a few degrees above the room; replace batteries if they use them.
- Note whether hot water is working, and whether the heating fails only during or after showers and baths.
- Photograph the boiler display and any message on it, and write down where the pressure gauge needle sits.
- From outside, look for snow or ice around the vent terminals and the condensate outlet. Don't dig at the pipes or try to thaw them.
- Listen: a pump that hums without moving water, or loud kettling from the boiler, is useful to mention.
When to stop: if you smell gas, get everyone outside, avoid switches, and call FortisBC's emergency line and 911 from outside. If a CO alarm sounds or anyone has a headache or nausea, leave and call 911. Also stop if you see water pooling under the boiler or tank, a gauge in the red, or a relief valve discharging.
Step by step, what happens when we arrive for a Triangle Tube repair?
We confirm the symptom, read the control's history, then trace the problem from the boiler through each zone and the indirect tank. A diagnostic and straightforward repair usually takes an hour or two; a heat-exchanger cleaning or circulator replacement can take most of a morning or afternoon.
- Ask when the heat drops out and whether hot water calls line up with it.
- Review the boiler control's stored lockouts and settings, including domestic hot water priority.
- Check each zone valve and circulator for power, movement and flow.
- Check the outdoor sensor reading against the real outdoor temperature.
- Inspect the intake, exhaust and terminals, then clear and test the condensate trap and drain.
- Check system pressure, the expansion tank and air elimination, and look for magnetite in the water.
- Test ignition and flame sensing, run a combustion analysis and confirm safe operation.
- Recommend any follow-up work, such as a heat-exchanger cleaning or adding a dirt separator, with a written quote.
Our rule of thumb for owners: if the boiler is sound and the trouble is pumps, valves or controls, repair it. If the heat exchanger is badly fouled or leaking and the boiler is older, it's worth seeing replacement options before you spend on major parts.
What drives the price of a Triangle Tube boiler repair?
The biggest factors are the part involved, how many zones and pumps are in play, how clean the system water is, and how hard the equipment is to reach. Every job gets an upfront flat-rate written quote before we begin — call (604) 704-0300 or email info@romaheating.ca.
- A control or sensor fix, versus a circulator, zone valve or heat-exchanger service.
- Whether the indirect tank is also part of the problem.
- How much magnetite and sediment is in the system and whether it needs flushing or a separator.
- Access in crawlspaces, garages and strata mechanical rooms.
- Part availability for your boiler's age.
More on our approach is on the boiler repair page.
How do I get on the schedule during a cold spell?
We book boiler repairs seven days a week and offer evening visits when the schedule allows. Cold spells bring a rush of calls, so we can't promise an arrival time, but sending details up front helps us prioritise properly and bring the likely parts.
Please send a photo of the boiler's rating plate if you can see it without removing covers, a photo of the display, the pressure reading, how many heating zones you have, whether hot water is affected, and any access notes such as a lockbox, strata manager contact, parking or pets. Book your Triangle Tube visit online, call, or email us.
Which Triangle Tube winter symptoms are urgent?
A gas smell, CO alarm, active leak or a home losing heat fast in freezing weather is urgent. Slow-to-warm zones, a noisy boiler or heat that only drops out during showers are real problems but can usually wait for a booked visit if the house is holding temperature.
| Symptom in cold weather | What's usually behind it | Wait or act now? | Your next move |
|---|---|---|---|
| Hot water fine, no heat during showers | Domestic hot water priority, slow recovery | Can wait | Note timing, book a check of controls and tank |
| One zone cold, others warm | Stuck zone valve or failed circulator | Can wait if pipes aren't at freezing risk | Book a repair, tell us which zone |
| Boiler short-cycles in the evening | Outdoor sensor, settings or restricted flow | A day or so | Photograph the display and book |
| Lockout after a frosty night | Frozen condensate drain or blocked terminal | Act soon | Look outside, don't thaw pipes yourself, call us |
| Loud rumbling or kettling | Magnetite and sediment in the heat exchanger | Book promptly | Schedule a diagnostic and cleaning quote |
| Gas smell or CO alarm | Possible leak or venting failure | Act now | Leave the home and call from outside |
Will a winter service help an older Triangle Tube boiler?
Often, yes. A service that clears the condensate system, checks pumps and valves and confirms combustion can stop a nuisance lockout from becoming a no-heat call later in January. It also tells you honestly how much life the boiler has left.
ROMA has served Greater Vancouver since 1999 as a TSBC-licensed gas contractor, bonded and insured, rated 4.8 stars from 221 Google reviews. Call (604) 704-0300 or email info@romaheating.ca to get your Triangle Tube looked at.
More questions we hear about this
Why do my Triangle Tube radiators go cold every time someone showers?
Most Triangle Tube boilers with an indirect tank are set to give hot water priority, so heating pauses while the tank recovers. On mild days you barely notice. In a cold snap, long showers or a slow-recovering tank can leave rooms cooling for a while. We check priority settings, tank recovery and boiler output to see whether it's normal behaviour or a fault.
Can a frozen condensate line shut down my Triangle Tube boiler?
Yes. Condensing boilers drain acidic water through a small line, and if the outdoor end freezes, the water backs up and the boiler shuts down to protect itself. Please don't pour boiling water on it or cut the pipe. Call us; we'll clear it, confirm the trap is working and look at rerouting or protecting the line so it doesn't happen again.
Is magnetite really a problem with Vancouver's soft water?
It is. Soft water doesn't leave mineral deposits, but steel pipe, older radiators and fresh top-up water all contribute to black magnetite sludge and sediment. In a Triangle Tube heat exchanger, that sludge narrows the passages, causes kettling and can trigger overheating lockouts. A cleaning and, where it makes sense, a dirt separator keep the boiler running cooler and quieter.
Do you service Triangle Tube indirect hot water tanks too?
Yes. We look at the boiler, its controls and the indirect tank together, because problems in one usually show up in the other during winter. If the tank is slow to recover or the coil is fouled, the heating suffers. Our written quote covers what each part of the system needs, so you can decide what to do now and what can wait.
What Greater Vancouver Homeowners Say
“Nelson worked hard to get the NTI unit fixed. He was always polite, courteous and on time.”
“As always Nelson was super efficient. Showed up on time and was quick to work. I had a full maintenance done on the fireplaces and furnace. He was awesome. I won’t use anyone else.”
“Excellent service. Andy had a spare Carrier inducer with him which saved us time.”
“Was very prompt to respond to our issues. Technician was scheduled for the day following my initial call.”
“Very professional heating company. Price is reasonable, excellent work.”
“Highly recommend this company. It was a pleasure dealing with Shawn and Nelson.”
“Professional and courteous technicians with attention to detail and customer needs.”
“Always great, friendly service. Serviced the hot water on-demand system. Honest and informative. Thanks!”
“Speedy response time, honest, and professional service from start to finish.”
Why Greater Vancouver Trusts ROMA Heating & Cooling
ROMA Heating & Cooling has installed, repaired and maintained heating and cooling systems across Metro Vancouver since 1999. Our team are TSBC-licensed gas fitters (Gas LGA0202903) and Red Seal-trained technicians — licensed, bonded and insured — and we back every job with upfront, flat-rate pricing and a 100% satisfaction guarantee. We hold a 4.8★ rating from 221+ Google reviews.
- Authorized for 30+ brands (Lennox, Carrier, Viessmann, Navien, Rheem & more)
- Upfront flat-rate pricing — no overtime or hidden fees
- Free, no-obligation estimates on new installations
- Locally owned & operated in Burnaby, BC
No Hidden Fees
Our service rates are transparent and easy to understand. You approve upfront, flat-rate pricing before we start — so you never get a bill you didn’t expect.
Licensed & Bonded
ROMA is a TSBC-licensed gas contractor (Gas LGA0202903). Our technicians are bonded, insured and Red Seal-trained — qualified for any heating or cooling system.
Free Estimates
We offer free, no-obligation estimates on new installations — furnaces, boilers, heat pumps, air conditioners, tankless and hot-water tanks.