The Navien NCB series shows up in plenty of Greater Vancouver homes, especially condos, townhomes and houses that replaced an old boiler and separate water tank with a single wall-hung unit. It’s often called a “tankless” because it makes hot water on demand, but it’s really a combi boiler: it also heats your home through radiators, baseboards or in-floor loops. Understanding that dual role makes troubleshooting much easier. ROMA Heating & Cooling repairs Navien NCB units across the region. We don’t claim to be a Navien authorized service provider; we’re a licensed gas contractor that works on these combis regularly.
Safety comes first: if there’s a smell of gas, get everyone out, don’t touch switches, and call FortisBC’s emergency line and 911 from outside. If a carbon monoxide alarm sounds, or occupants feel headachy, drowsy or ill, leave and call 911.
How does a Navien NCB combi work?
When the thermostat calls for heat, the NCB fires its burner and circulates heated water through your heating system. When someone opens a hot tap, a flow sensor detects it and the unit switches — using an internal diverter — to heat domestic water through a separate heat exchanger. Domestic hot water usually takes priority, so heating pauses briefly while a tap runs. The unit vents through sealed pipe and, as a condensing appliance, drains acidic condensate through a trap.
What commonly goes wrong with NCB units?
Call a licensed ROMA gas technician — (604) 704-0300
| Symptom | Possible causes | Where we look |
|---|---|---|
| Heat works, no hot water | Flow sensing, diverter, clogged inlet filter | Domestic side components |
| Hot water works, no heat | Diverter, circulation, thermostat, low pressure | Heating side and controls |
| Pressure keeps dropping | Leak, relief valve, expansion tank, air vent | Heating circuit |
| Lockouts with an error code | Ignition, flame sensing, venting, condensate | Burner, vent and drain |
| Noisy operation or kettling | Sludge in the heating loop, air, low flow | System water and circulation |
| Hot water fluctuates | Low flow, sediment in the domestic exchanger, gas supply | Flow, flushing, gas pressure |
Error code meanings depend on the specific model, so we read them against the documentation for your unit rather than generic lists.
Why does system pressure matter on an NCB?
The heating side of an NCB is a sealed, pressurized loop. If pressure drops too low, the unit stops firing for heating to protect itself. Slow pressure loss usually means a leak, a weeping relief valve, an air vent problem or an expansion tank that has lost its charge. Topping up repeatedly without finding the cause adds oxygen to the system, which feeds corrosion. We find and fix the loss.
What does sludge have to do with it?
Many NCB units in Greater Vancouver were connected to existing heating systems with older steel radiators or piping. Our soft water means mineral scale isn’t the issue, but those systems produce magnetite sludge as they slowly corrode, and sludge can foul the NCB’s heat exchanger and pumps, causing noise, overheating and lockouts. If we see signs of it, we’ll recommend a system clean and a magnetic filter.
What can you check before calling?
- Note the error code and whether heating, hot water or both are affected.
- Read the pressure gauge on the unit or nearby piping.
- Check the thermostat is calling for heat and has fresh batteries.
- Look outside at the vent terminal for blockages.
- Look for water under the unit or at the condensate line.
One reset is fine. Don’t open the cabinet, add water without guidance, or attempt a flush yourself.
How does ROMA repair an NCB?
- Read the code and fault history; identify the model.
- Observe heating and hot water modes.
- Test ignition, flame sensing, gas pressure, venting and condensate.
- Check flow sensing, the diverter, inlet filter and domestic heat exchanger.
- Check pressure, expansion tank and circulation on the heating side.
- Explain the cause, quote a flat rate in writing, repair and test both modes.
What about NCB units in condos?
Many NCBs live in condo closets, where the unit heats the suite through baseboards or in-floor loops and supplies every tap. Venting usually exits through a balcony or exterior wall, and condensate drains to building plumbing. Strata buildings bring access rules and contractor hours, and a leak from the relief valve or condensate line can reach a neighbour quickly. We plan condo visits around the building’s requirements and pay close attention to vents and drains, which cause a large share of NCB lockouts in towers across Burnaby, Richmond and Coquitlam.
Is an NCB worth repairing or should it be replaced?
Most NCB faults are repairable: flow sensors, diverter components, igniters, flame rods, condensate parts, expansion tanks and pumps. Replacement becomes a real consideration when a heat exchanger fails, especially on an older unit, or when several major parts are wearing out together. We’ll give you written prices for both, and if replacement makes sense, we’ll discuss whether another combi or a boiler with a separate tank suits your home better.
How should an NCB be maintained?
Annually: clean the combustion side and check the burner, clear the condensate trap, flush the domestic heat exchanger and clean the inlet filter, check heating pressure and the expansion tank, review system water condition, inspect venting and test combustion.
Where do we service Navien NCB units?
Condos and townhomes in Burnaby, Richmond, Coquitlam and New Westminster; houses in Vancouver, the North Shore, Surrey, Delta, White Rock and Langley.
Boilers and combis have been a big part of ROMA’s work since 1999. We’re licensed through Technical Safety BC, fully bonded and insured, rated 4.8 stars across 221 Google reviews, and on the road 7 days a week from Burnaby. See our boiler repair page or book an NCB repair.
Tell us what you have — the brand, the model, and what it’s doing — and we’ll come back with the honest picture. Call (604) 704-0300 and ROMA will get your Navien NCB heating the house and the water again.
Learn more about ROMA’s related services.
Need a licensed gas technician in Greater Vancouver?
ROMA Heating & Cooling has served Metro Vancouver since 1999 — TSBC-licensed (Gas LGA0202903), bonded & insured, 4.8★ from 221 Google reviews. Upfront flat-rate pricing, free estimates on installs, 0% financing (OAC), no hidden fees, 7 days a week.
Frequently Asked Questions
Is the Navien NCB a tankless water heater or a boiler?
It’s a combi boiler. The NCB heats your home through radiators, baseboards or in-floor loops and also makes domestic hot water on demand, which is why people often call it a tankless. Because it does both jobs, a fault can affect heating, hot water or both, and diagnosis covers each side.
Why does my Navien NCB make hot water but not heat the house?
Possible causes include the internal diverter not switching to heating, low system pressure, a circulation problem or a thermostat issue. Since hot water works, the burner and gas supply are probably fine. ROMA tests the heating side, pressure and controls to find the actual fault.
Why does my Navien NCB keep losing pressure?
Slow pressure loss usually means water is escaping from the heating loop through a leak, a weeping relief valve or an air vent, or that the expansion tank has lost its charge. Repeated top-ups add oxygen that feeds corrosion. ROMA traces and fixes the source rather than just refilling.
Does sludge affect Navien NCB units in Greater Vancouver?
It can when the NCB is connected to older steel radiators or piping. Soft local water means scale isn’t the concern, but corroding steel produces magnetite sludge that can foul the heat exchanger and pumps. A system clean and magnetic filter help protect the unit.
Reviewed by the ROMA Heating & Cooling team — TSBC-licensed gas contractor (Gas LGA0202903), serving Greater Vancouver since 1999. Updated September 2026.
What Greater Vancouver Homeowners Say
“Nelson worked hard to get the NTI unit fixed. He was always polite, courteous and on time.”
“As always Nelson was super efficient. Showed up on time and was quick to work. I had a full maintenance done on the fireplaces and furnace. He was awesome. I won’t use anyone else.”
“Excellent service. Andy had a spare Carrier inducer with him which saved us time.”
“Was very prompt to respond to our issues. Technician was scheduled for the day following my initial call.”
“Very professional heating company. Price is reasonable, excellent work.”
“Highly recommend this company. It was a pleasure dealing with Shawn and Nelson.”
“Professional and courteous technicians with attention to detail and customer needs.”
“Always great, friendly service. Serviced the hot water on-demand system. Honest and informative. Thanks!”
“Speedy response time, honest, and professional service from start to finish.”
Why Greater Vancouver Trusts ROMA Heating & Cooling
ROMA Heating & Cooling has installed, repaired and maintained heating and cooling systems across Metro Vancouver since 1999. Our team are TSBC-licensed gas fitters (Gas LGA0202903) and Red Seal-trained technicians — licensed, bonded and insured — and we back every job with upfront, flat-rate pricing and a 100% satisfaction guarantee. We hold a 4.8★ rating from 221+ Google reviews.
- Authorized for 30+ brands (Lennox, Carrier, Viessmann, Navien, Rheem & more)
- Upfront flat-rate pricing — no overtime or hidden fees
- Free, no-obligation estimates on new installations
- Locally owned & operated in Burnaby, BC
No Hidden Fees
Our service rates are transparent and easy to understand. You approve upfront, flat-rate pricing before we start — so you never get a bill you didn’t expect.
Licensed & Bonded
ROMA is a TSBC-licensed gas contractor (Gas LGA0202903). Our technicians are bonded, insured and Red Seal-trained — qualified for any heating or cooling system.
Free Estimates
We offer free, no-obligation estimates on new installations — furnaces, boilers, heat pumps, air conditioners, tankless and hot-water tanks.
