The tank is up in the attic, the shower is cold, and the family is looking at you. A gas water heater with no hot water follows the same chain regardless of where it stands: gas in, pilot flame, thermocouple holds it, control valve opens, burner fires, heat goes in. The cavity changes the likelihood, but never the order of the diagnosis.
What is the first thing to check?
The control position and the gas supply. A knob knocked to vacation, or the supply valve to the appliance closed by the previous homeowner for a reason, is a staggeringly common find. Then the pilot: does it hold? Then the thermocouple sensing, then the burner. Each stage is the one that releases the next a little easier.
Why is the pilot often the root when the tank sits in an attic?
Call a licensed ROMA gas technician — (604) 704-0300
Cold drafts are the honest explanation. The attic cavity breathes with the roof on blustery days, and a draft path over the pilot window can pick the flame clean off the sensor, dropping it the instant it lights. A pilot that will not stay lit is a repeat caller in attic tanks, and the vent termination or the air intake often needs the correction, not the pilot.
What else shows up in closets?
Dust and the storage compaction. A closet cavity with a door that closes tight starves the burner’s air path, the flame gets soft, the thermocouple reads weak, and the safety drops the burner. Junk hauled in front of the door does the same. The airflow check is a real part of the diagnosis, not a courtesy.
How does a technician take over once the supply is confirmed?
Continuous verification of the pilot flame, thermocouple millivolt and the valve’s hold, then the burner’s ignition sequence watched through to a clean burn. The technician checks the vent draft and the air path in the cavity, and the flame pattern against the manual. Anything that fails gets replaced or adjusted before leaving.
What if the tank has hot water in it but the taps run cold?
Then the problem is between the tank and the shower. A mixing fault, a stuck valve ahead of the fixture, a closed isolation valve, or a fixture cartridge sticking; rarely a recirculation line path. ROMA works from the tank to the tap, and the honest answer is proven at the sink you use.
Is there a quick thing I can do before calling?
Check the control is not in vacation, see that nothing is shut at the supply, and listen for the burner during the recovery cycle in the cavity after a short dish of hot water. Beyond that, leave the gas and electrical parts to the licence. A cold shower is an irritant — a tampered gas fitting is not.
How long does a no-hot-water visit take?
A pilot and a control fix is often a same-visit job; a combustion analysis takes longer only when the diagnosis points that way. ROMA tells you on the phone what you can expect and quotes the realistic window before the truck arrives.
Why is the recovery slow even when the burner runs all day?
A burner that lights but only warms the water slowly is the third story in the chain: the sediment at the tank bottom or a slowly closing gas supply. The sediment acts as an insulator between the flame and the water; the burner cycles against a tank that cannot take the full heat. ROMA confirms the gas pressure under load and the flame pattern, then flushes the tank, and the recovery hours return to their normal span.
Can a whole-house event, a festival, or a family visit trigger the no-hot-water day?
Yes, in the honest sense of demand. A tank sized for the daily routine is asked to do more on the big days, and the recovery gets consumed by the first two showers. The tank is not failing; it is meeting a load with a margin it was never given. ROMA reviews the demand profile in the visit and tells you whether the tank is fine with smarter staging, or whether the next big guest week deserves a different size.
ROMA serves this equal part of the house and the rest of it too — book a visit here, or see the hot water tank section of the site for what a ROMA call looks like.
| Check | What it confirms |
|---|---|
| Pilot holds? | The flame sensing story |
| Burner fires under call? | The gas and control wire |
| Gas pressure on fire | Supply delivery condition |
| Cavity air path | Draft and airflow health |
Smell gas? Get everyone out and call the gas emergency line, then 911 from outside. Suspect carbon monoxide? Leave and call 911. ROMA Heating & Cooling, a licensed gas contractor (Gas LGA0202903), tests water heaters, their venting, and CO alarms once the space is cleared.
Tell us what you have — the brand, the model, and what it’s doing — and we’ll come back with the honest picture. Call ROMA Heating & Cooling at (604) 704-0300.
Need a licensed gas technician in Greater Vancouver?
ROMA Heating & Cooling has served Metro Vancouver since 1999 — TSBC-licensed (Gas LGA0202903), bonded & insured, 4.8★ from 221 Google reviews. Upfront flat-rate pricing, free estimates on installs, 0% financing (OAC), no hidden fees, 7 days a week.
Frequently Asked Questions
Why would my attic tank heater out hot water one day and nothing the next?
In an attic tank, the most common day-to-day drop is a pilot that is right on the edge: the flame holds during the day, a cold night draft over the vent picks it off, and the next morning there is no heat recovery. ROMA keeps the pilot on a verified path and fixes the draft, not just the flame.
Do I need to relight the pilot myself?
Turning a main control and lighting a pilot on a gas appliance is a licensed task. A lit pilot confirms the gas is present, but a lit pilot also confirms your clearance to work the appliance. ROMA lights it the proper way, and if it fails to hold, we verify the vent and the air path before the part.
Why would a water heater stop heating even though the pilot is on?
The pilot is the flame, the thermocouple is the sensing, and the control valve is the gate. If the pilot is on but the burner never fires, the thermocouple reading or the control valve logic is at fault or the supply to the burner is interrupted. ROMA meters the link and isolates which stage is holding the gate.
Can a closet with poor air really stop the heater from heating?
Yes. A gas burner needs a measured air supply, and a sealed closet door chokes it. The result is a weak flame, soot, and outages. ROMA checks the cavity’s openings and the vent draft before touching any part, and the airflow correction often saves a burn hour every day.
My tank makes noise but the water stays cold — what is happening?
Rumbling with no temperature gain suggests the burner is firing and the heat is being punished by sediment sitting thick at the bottom of the tank, or the burner flame is sooty. A flush with the burner inspection usually restores recovery. ROMA confirms the fire is clean first, then supervises the flush.
Reviewed by the ROMA Heating & Cooling team — TSBC-licensed gas contractor (Gas LGA0202903), serving Greater Vancouver since 1999. Updated September 2026.
What Greater Vancouver Homeowners Say
“Nelson worked hard to get the NTI unit fixed. He was always polite, courteous and on time.”
“As always Nelson was super efficient. Showed up on time and was quick to work. I had a full maintenance done on the fireplaces and furnace. He was awesome. I won’t use anyone else.”
“Excellent service. Andy had a spare Carrier inducer with him which saved us time.”
“Was very prompt to respond to our issues. Technician was scheduled for the day following my initial call.”
“Very professional heating company. Price is reasonable, excellent work.”
“Highly recommend this company. It was a pleasure dealing with Shawn and Nelson.”
“Professional and courteous technicians with attention to detail and customer needs.”
“Always great, friendly service. Serviced the hot water on-demand system. Honest and informative. Thanks!”
“Speedy response time, honest, and professional service from start to finish.”
Why Greater Vancouver Trusts ROMA Heating & Cooling
ROMA Heating & Cooling has installed, repaired and maintained heating and cooling systems across Metro Vancouver since 1999. Our team are TSBC-licensed gas fitters (Gas LGA0202903) and Red Seal-trained technicians — licensed, bonded and insured — and we back every job with upfront, flat-rate pricing and a 100% satisfaction guarantee. We hold a 4.8★ rating from 221+ Google reviews.
- Authorized for 30+ brands (Lennox, Carrier, Viessmann, Navien, Rheem & more)
- Upfront flat-rate pricing — no overtime or hidden fees
- Free, no-obligation estimates on new installations
- Locally owned & operated in Burnaby, BC
No Hidden Fees
Our service rates are transparent and easy to understand. You approve upfront, flat-rate pricing before we start — so you never get a bill you didn’t expect.
Licensed & Bonded
ROMA is a TSBC-licensed gas contractor (Gas LGA0202903). Our technicians are bonded, insured and Red Seal-trained — qualified for any heating or cooling system.
Free Estimates
We offer free, no-obligation estimates on new installations — furnaces, boilers, heat pumps, air conditioners, tankless and hot-water tanks.